How to Install and Operate the Hydraulic Press

How to Install and Operate the Hydraulic Press

Table of Contents

Filling Hydraulic Oil

O-rings of Hydraulic Press

(O-rings)

After the machine and oil tank are lifted to the appropriate height at the factory, connect the oil pipe and ensure the joints have O-rings to prevent oil leakage. The machine requires No. 46 anti-wear hydraulic oil. Initially, fill the tank completely, as the new machine contains no oil. The first operation will allow hydraulic oil to flow into the cylinder and fill the liquid tank. After running, if the oil level in the main tank drops below 50%, top up the hydraulic oil.

Liquid Level Gauge of Hydraulic Press

(Liquid Level Gauge)

Install limit Switches And Connect Power

limit Switches of Hydraulic Press

(limit Switches)

After adding oil, install the limit switches in three groups: upper, middle, and lower. Each switch is labeled for installation in sequence. Once installed, adjust the probe distance from the worktable to within 5mm. The limit switch travel can be adjusted based on product requirements.

Next, install the mobile button box by connecting and tightening the aviation plugs.

Connect the L1, L2, and L3 power cables, close all air switches, and turn on the electric lock. Check that the indicator light is on and the emergency stop switch is open. After pressing the pneumatic button, press the stop button and observe the motor fan rotation. If it rotates counterclockwise, swap any two of the L1, L2, or L3 power cables to ensure clockwise rotation.

Motor of Hydraulic Press

(Motor)

Thermal Relay Troubleshooting

Thermal Relay of Hydraulic Press

(Thermal Relay)

If the electric lock indicator doesn’t light up after powering on, the thermal protection relay may have tripped during transport. To reset, press the blue button and ensure the green pin is in place.

Machine Test

Turn the knob to adjust the master cylinder and set the ejector cylinder to manual. Press the hydraulic start button to activate the motor, then press and hold the master cylinder return button. Keep holding it, as the new machine requires time to fill the cylinder with hydraulic oil. The worktable will rise to the top. Continue pressing the master cylinder down button until the table reaches the lowest position, repeating 2–3 times. Once the cylinder is filled with hydraulic oil, the excess oil will flow back into the fill tank. will return to the main cylinder. Some shaking during the test run is normal.

Next, press the top cylinder ejector button to its highest stroke, then press the return button. Repeat the up-and-down motion 2–3 times to remove air and fill the cylinder with oil. Install the top cylinder limit switches—lower and upper—by first lowering the ejector cylinder to the lower dead center to install the lower switch, then raising it to the highest position to install the upper switch.

Machine Test of Hydraulic Press

(Machine Test)

Manual Mode Tutorial

  1. During adjustment and manual operation, press and hold the button to move; release the button to stop.
  2. The downward adjustment is slow, ideal for mold installation and testing.
  3. When holding down the return button, there will be a delay before the master cylinder moves. The ejector cylinder limit height should be set based on the mold’s needs, typically 5-10 mm above the lower mold. During production, the master cylinder moves quickly until it contacts the workpiece, then slows down for pressing. To increase production efficiency, minimize the slow-down height based on product requirements.

Attention:

  1. The pressure gauge will not show pressure during no-load tests without molds.
  2. Avoid exceeding the lower limit stroke pressure during trials or use.
  3. The mold height must be greater than the minimum closing height to ensure proper pressing.
Mobile Button Box of Hydraulic Press

(Mobile Button Box)

Automatic Mode Tutorial

  1. Master Cylinder Auto Mode: The master cylinder operates automatically. The ejector cylinder can be set to manual or stopped, not participating in the action.
  2. Ejecting Action:
  • Press both downward buttons.
  • The master cylinder moves down quickly, then slows at the middle limit.
  • It stops at the lower limit, then automatically returns and stops at the upper limit.
  • The ejector cylinder moves up to the upper limit, then returns to the lower limit and
  1. Stretching Action:
  • Press both downward buttons.
  • The master cylinder moves down quickly, then slows at the middle limit.
  • The ejector cylinder moves down, stops at the lower limit, and returns automatically.
  • The ejector cylinder then moves up to the upper limit and stops.
  1. Downward Stop Limit: The master cylinder’s downward stop can be controlled by either the limit or stroke control, adjustable using the fixed-range pressure knob.

 

Electrical Cabinet of Hydraulic Press

(Electrical Cabinet)

Pressure Adjustment

Pressure Adjustment of Hydraulic Press

(Pressure Adjustment)

Place the mold on the top cylinder, turn the system remote knob counterclockwise to set the pressure to minimum, then press the downward button. The master cylinder will move down slowly or stop at the middle limit due to the low pressure. Turn the knob clockwise to increase the pressure, allowing the master cylinder to continue downward. The pressure gauge will show pressure only when the master cylinder begins to press into the mold.

When the black pointer on the pressure gauge touches the red pointer, stop increasing pressure. For the stretching function, adjust the clamping pressure of the ejector cylinder. The ejector cylinder’s pressure gauge shows the pressure, which can be adjusted remotely by turning the knob clockwise to increase pressure or counterclockwise to decrease it, based on product requirements

Conclusion

Hydraulic Products of Hydraulic Press

(Hydraulic Products)

Adjusting hydraulic and clamping pressure is crucial for optimal performance in mold pressing and stretching operations.​ Proper adjustments ensure efficient machine operation tailored to specific product requirements. Regular monitoring and fine-tuning of these pressure settings help maintain smooth and reliable functionality.